Product ID: 6087

STCAL Spark Tester Calibration Unit & Optional STCAL-SM Fault Sensitivity Module

Product Overview

The STCAL can calibrate any AC, DC, or high-frequency spark tester regardless of manufacturer and will generate a traceable certificate of calibration.

The STCAL-SM is an optional accessory for the STCAL that adds sensitivity verification.

Enquire about this product

Clinton Instrument Company introduces a modular calibration system for AC mains, high frequency, and DC spark testers – STCAL.
The STCAL-SM verifies spark tester functionality by determining that the system is detecting all necessary faults.

Key Features: 

  • System includes:
    • Separate high- and low-frequency voltmeters.
    • A case containing a Windows-based touch-screen tablet and connecting cables.
  • Calibration procedure:
    • Select the appropriate voltmeter and cables.
    • Connect the voltmeter to the spark tester and tablet.
    • Choose a spark tester profile from the touch screen menu.
    • Follow the on-screen directions for completing the calibration.
  • Generates a certificate of calibration:
    • Suitable for download, printing, and storage in the customer’s computer.
    • Data is traceable to NIST standards when the STCAL is incorporated into an effective quality assurance program.
  • STCAL components:
    • Light enough to be carried to hard-to-reach locations where spark testers are sometimes situated.
  • Calibration capabilities:
    • Calibrates AC mains spark testers to 30kV.
    • Calibrates high frequency units to 15kV.
    • Calibrates DC spark testers to 40kV.
  • Optional components:
    • STCAL-SM Sensitivity Module:
      • Rotating spark gap controls arc duration and gap distance.
      • Operator selects the type of test to be performed.
      • SM displays the detection current and the required number of controlled faults the spark tester must identify to meet the norm.
      • After the test, operator compares the SM fault count to the faults counted by the spark tester to determine its conformity with the specification.

Sample Systems:

  • STCAL Calibration System
  • STCAL Calibration System with HF-15A Spark Tester
  • Optional STCAL-SM Sensitivity Module

Major Features:

  • Verify spark tester detection circuit

  • Meet requirements of IEC-62230, EN 50356, and NEMA WC-56

PARAMETERVALUE
Operating ModesHigh-Frequency Calibrator (3kHz) - 500v-15kV RMS, LowFrequency Calibrator (mains and DC) - 1kV-30kV RMS / 100v-40kV DC
Input Frequency RangeIEC/HF, IEC/AC, IEC/DC, NEMA/HF
Input VoltageIEC/HF - 3.0kV RMS
IEC/AC - 3.0kV RMS
IEC/DC - 5.0kV DC
NEMA/HF - 3.0kV RMS
Display TypeLED Counter
Power Requirements100-240VAC 48-63Hz, Power supply is self-adjusting