Clinton Instrument Company introduces a modular calibration system for AC mains, high frequency, and DC spark testers – STCAL.
The STCAL-SM verifies spark tester functionality by determining that the system is detecting all necessary faults.
Key Features:
- System includes:
- Separate high- and low-frequency voltmeters.
- A case containing a Windows-based touch-screen tablet and connecting cables.
- Calibration procedure:
- Select the appropriate voltmeter and cables.
- Connect the voltmeter to the spark tester and tablet.
- Choose a spark tester profile from the touch screen menu.
- Follow the on-screen directions for completing the calibration.
- Generates a certificate of calibration:
- Suitable for download, printing, and storage in the customer’s computer.
- Data is traceable to NIST standards when the STCAL is incorporated into an effective quality assurance program.
- STCAL components:
- Light enough to be carried to hard-to-reach locations where spark testers are sometimes situated.
- Calibration capabilities:
- Calibrates AC mains spark testers to 30kV.
- Calibrates high frequency units to 15kV.
- Calibrates DC spark testers to 40kV.
- Optional components:
- STCAL-SM Sensitivity Module:
- Rotating spark gap controls arc duration and gap distance.
- Operator selects the type of test to be performed.
- SM displays the detection current and the required number of controlled faults the spark tester must identify to meet the norm.
- After the test, operator compares the SM fault count to the faults counted by the spark tester to determine its conformity with the specification.
- STCAL-SM Sensitivity Module:
Sample Systems:
- STCAL Calibration System
- STCAL Calibration System with HF-15A Spark Tester
- Optional STCAL-SM Sensitivity Module
Major Features:
-
Verify spark tester detection circuit
-
Meet requirements of IEC-62230, EN 50356, and NEMA WC-56